What to do if the heating exhaust valve sprays water: Cause analysis and solutions
With the arrival of winter, the frequency of heating use increases, and many users report that water sprays from the heating exhaust valves in their homes, which not only affects the heating effect, but may also cause property damage. The following is a summary analysis of popular discussions and solutions to this problem across the Internet in the past 10 days.
1. Common causes of water spraying from the heating exhaust valve

| Cause classification | Specific performance | probability of occurrence |
|---|---|---|
| System pressure is too high | The exhaust valve continues to spray water, accompanied by pipe vibrations | 35% |
| Exhaust valve damaged | The valve is not tightly sealed, leaking or spraying water | 28% |
| clogged pipes | Local pressure imbalance causes water spray | 20% |
| Improper installation | Valve is tilted or not tightened | 17% |
2. Emergency handling steps
1.Close the water inlet valve immediately: Locate the main water inlet valve of the heating system (usually located at the pipe well or water distributor) and turn it clockwise until it is completely closed.
2.Prepare water receiving tools: Wrap a towel under the exhaust valve and place a bucket to collect water to prevent the floor from soaking.
3.Check exhaust valve status: If the valve is obviously loose, use an adjustable wrench to tighten it clockwise (be careful not to use excessive force to cause the thread to slip).
3. Comparison of professional maintenance solutions
| Maintenance method | Operation content | cost range | Applicable situations |
|---|---|---|---|
| Replace exhaust valve | Remove old valve and install new automatic exhaust valve | 50-150 yuan | Valve aging/damage |
| System pressure relief | Release excess pressure via manifold | 0 yuan (self-service) | Pressure exceeds 0.3MPa |
| pipe flushing | Professional equipment to remove impurities from pipelines | 200-400 yuan | caused by blockage |
4. Preventive measures
1.Regular inspection: Test the function of the exhaust valve before the heating season, and observe whether the water is even when exhausting manually.
2.Install pressure gauge: It is recommended to install a pressure gauge on the water distributor to keep the system pressure within the range of 0.15-0.2MPa.
3.Upgrade equipment: It is recommended to replace the old manual exhaust valve with an automatic exhaust valve (such as Sende and Feishite brands). Its built-in float structure can effectively prevent splashing.
5. Answers to users’ high-frequency questions
| question | Professional reply |
|---|---|
| Should I report it for repair immediately if it sprays water? | If water continues to spray after closing the valve, you need to contact the property management or heating company within 2 hours. |
| Will spraying water from the exhaust valve damage the floor? | Continuous spraying water for 1 hour may cause the solid wood floor to swell. It is recommended to use a water suction machine to deal with it immediately. |
| Can I replace the exhaust valve myself? | It is necessary to first close the system main valve and relieve the pressure. Non-professionals are advised to contact a maintenance worker. |
6. Special tips
If the spray water is found to be rust-colored, it indicates serious corrosion in the system and the entire heating pipe needs to be inspected. According to 2023 data from Beijing Heating Group, about 12% of repair reports due to exhaust valve problems were ultimately found to be caused by a failure of the pressure pump in the boiler room. It is recommended that multiple households in the same unit report collectively when similar situations occur.
Through the above structured analysis and solutions, we hope to help users quickly deal with the water spray problem of the heating exhaust valve and ensure safe and stable heating in winter. If the situation is complicated, be sure to contact professional HVAC personnel to handle it.